{"id":121272,"date":"2024-02-27T14:41:12","date_gmt":"2024-02-27T07:41:12","guid":{"rendered":"https:\/\/prayrug.com\/products\/kl3361-bus-terminal-dau-vao-analog-1-kenh-dien-ap-%c2%b120-mv-15-bit-chuc-nang-oscilloscope"},"modified":"2024-02-27T14:46:47","modified_gmt":"2024-02-27T07:46:47","slug":"kl3361-bus-terminal-1-channel-analog-input-voltage-%c2%b120-mv-15-bit-oscilloscope-function","status":"publish","type":"product","link":"https:\/\/prayrug.com\/en\/products\/kl3361-bus-terminal-1-channel-analog-input-voltage-%c2%b120-mv-15-bit-oscilloscope-function","title":{"rendered":"KL3361 | Bus Terminal, 1-channel analog input, voltage, \u00b120 mV, 15 bit, oscilloscope function\u00a0"},"content":{"rendered":"
KL3361 | Bus Terminal, 1-channel analog input, voltage, \u00b120 mV, 15 bit, oscilloscope function\u00a0<\/span><\/p>\n <\/p>\n The KL3361 analog input terminal makes it possible to perform non-central preliminary processing of analog values. It is designed to measure a voltage in the mV range, such as occurs at a strain gauge full bridge. For operation of the full bridge, the KL3361 also has an internal 5 V supply. The input values are digitized with a 14 bit resolution and written into an internal memory. An efficient processor can pre-process the values. Limit values and maximum and minimum values can be determined or monitored. The KL3361 can also carry out envelope curve monitoring. A trigger starts the cyclical processes. The result or all the measured values are transported to the higher-level automation unit.<\/span><\/p>\n Number of inputs<\/span> 1 analog, 1 trigger<\/span><\/p>\n Power supply<\/span> via the K-bus<\/span><\/p>\n Signal voltage<\/span> UIN: -16\u2026+16 mV<\/span><\/p>\n Signal voltage UIN<\/span> -20\u2026+20 mV<\/span><\/p>\n Technology<\/span> high-speed data logger<\/span><\/p>\n Internal resistance<\/span> > 1 M\u03a9 (UB)<\/span><\/p>\n Supply voltage<\/span> 5 V DC, max. 20 mA<\/span><\/p>\n Conversion time<\/span> < 100 \u00b5s, configurable (10 \u00b5s with fast sampling mode)<\/span><\/p>\n Sampling rate<\/span> < 100 \u00b5s, configurable (10 \u00b5s with fast sampling mode)<\/span><\/p>\n Resolution<\/span> 14 bit + sign<\/span><\/p>\n Measurement error\/ uncertainty<\/span> < \u00b11 % (relative to full scale value)<\/span><\/p>\n Internal memory<\/span> 32 kbytes<\/span><\/p>\n Current consumption power contacts<\/span> \u2013 (no power contacts)<\/span><\/p>\n Current consumption K-bus<\/span> typ. 120 mA with external SG power supply, typ. 140 mA with internal SG power supply from terminal (4 x 350 \u03a9)<\/span><\/p>\n Bit width in the process image<\/span> input\/output: 1 x 16 bit data (1 x 8 bit status, 1 x 8 bit control)<\/span><\/p>\n Special features<\/span> high-speed strain gauge analysis (for all fieldbuses)<\/span><\/p>\n Weight<\/span> approx. 55 g<\/span><\/p>\n Operating\/storage temperature<\/span> 0\u2026+55 \u00b0C\/-25\u2026+85 \u00b0C<\/span><\/p>\n Relative humidity<\/span> 95 %, no condensation<\/span><\/p>\n Vibration\/shock resistance<\/span> conforms to EN 60068-2-6\/EN 60068-2-27<\/span><\/p>\n EMC immunity\/emission<\/span> conforms to EN 61000-6-2\/EN 61000-6-4<\/span><\/p>\n Protect. rating\/installation pos.<\/span> IP20\/variable<\/span><\/p>\n Approvals\/markings<\/span> CE, UL, ATEX, IECEx<\/span><\/p>\n Pluggable wiring<\/span> for all KSxxxx Bus Terminals<\/span><\/p>\n Ex marking<\/span> ATEX:<\/span><\/p>\n II 3 G Ex ec IIC T4 Gc<\/span><\/p>\n IECEx:<\/span><\/p>\n Ex ec IIC T4 Gc<\/span><\/p>\n >>> Refer to technical document:
<\/p>\n